Сегодня 12 октября 2024
Медикус в соцсетях
 
Задать вопрос

ЗАДАТЬ ВОПРОС РЕДАКТОРУ РАЗДЕЛА (ответ в течение нескольких дней)

Представьтесь:
E-mail:
Не публикуется
служит для обратной связи
Антиспам - не удалять!
Ваш вопрос:
Получать ответы и новости раздела
20 мая 2002 00:00   |   Akihiko Usui, MD*a, Yasuya Inden, MDb, Shinichi Mizutani, MDa, Yasushi Takagi, MDa, Toshiaki Akita, MDa, Yuichi Ueda, MDa

Repetitive atrial flutter as a complication of the left-sided simple maze procedure

Background. Of 41 patients who had undergone a left-sided simple maze procedure, 4 (9.8%) developed repetitive tachycardia due to atrial flutter, and required radiofrequency catheter ablation. Linear ablation of the right atrial isthmus was effective to treat atrial flutter.
Methods. We conducted an electrophysiologic study of atrial flutter and determined its reentry circuit on the atrium. We consider how to reduce atrial flutter after the left-sided simple maze procedure.
Results. Common atrial flutter through the right atrial isthmus was induced in all 4 patients, and linear ablation on the right atrial isthmus was effective in 3 of these. An incisional atrial flutter around the right atriotomy was also induced in 2 of 4 patients; both were successfully treated by linear ablation between the right atriotomy and the inferior vena cava.
Conclusions. Common atrial flutter through the right atrial isthmus is a risk after the left-sided simple maze procedure. When a left-sided simple maze procedure is performed, sufficient cryoablation on the right atrial isthmus of the arrested heart should be administered to prevent postoperative atrial flutter.

Поделиться:




Комментарии
Смотри также
20 мая 2002  |  00:05
Coronary end-to-side sleeve anastomosis using adhesive in off-pump bypass grafting in the pig
Background. In the exploration of facilitated coronary anastomosis strategies, we assessed a new octyl-cyanoacrylate adhesive in combination with a modified end-to-side sleeve anastomosis in off-pump
20 мая 2002  |  00:05
Hemodynamic stability during 17 years of the Carpentier-Edwards aortic pericardial bioprosthesis
Background. Long-term stability of the hemodynamic performance of commercially available Carpentier-Edwards stented bovine pericardial aortic bioprostheses (Perimount RSR) is unknown. To anticipate
20 мая 2002  |  00:05
Long-term results of aortic valve regurgitation after repair of ruptured sinus of valsalva aneurysm
Background. We reviewed our 35-year-experience to investigate the determinants of long-term results of aortic valve regurgitation (AR) after surgical repair of ruptured sinus of Valsalva aneurysms
20 мая 2002  |  00:05
Long-term survival and quality of life in cardiac surgical patients with prolonged intensive care unit length of stay
Background. Patients with prolonged intensive care unit (ICU) stays after cardiac operations are labor intensive and expensive. We sought to determine whether exhaustive ICU efforts result in
20 мая 2002  |  00:05
Endothelial cell injury induced by preservation solutions: a confocal microscopy study
Background. We evaluated the effects of standard preservation solutions on cultured human greater saphenous vein endothelial cells. Methods. Endothelial cells (eight strains) were preincubated